OSCILLOSCOPE, 20MHz
This is a portable type of Oscilloscope for two traces. The band width is 0-20MHz. The instrument is of easy operation with comfortable controls. Its reasonable structure and technology makes it convenient to repair and calibrate.
- Dual Trace Dual Channel Oscilloscope with Component Test Facility
- Bandwidth : 20MHz
- Full bandwidth sweeping circuit is used in the sweeping system
- The flexible and convenient triggering mode has the functions for
selecting signals from one channel or triggered by Ext signals - ALT trigger to observe signals from two irrelative channels
- The instrument has the functions of TV-H / TV-V synchronization and
trigger-lock to observe all kinds of signals stably - From the terminal for trigger input, CH1 and CH2 signals can be output along
with the triggering channel to connect the Ext frequency counter - Y deflection operation : Y1, Y2, ALT, CHOP, ADD, mode X-Y
- Vertical Deflection : 5mV/Div to 20V/Div in factor 1-2-5 sequence in 12 steps
- Rising time : < 18nS
- Maximum Input Voltage : 400V (DC +Acp-p)
- Triggering Source : Y1, Y2, ALT, POWER, EXT
- Trigger Coupling : AC/DC (EXT), NORM/TV-H, TV-V
- Horizontal Sweep Mode : AUTO, TRIG, LOCK, SINGLE
- Sweep time factor : 0.1uS/div to 0.2s/div in 1-2-5 sequence in 20 steps
- Magnification : x10
- X-Ymode input : X-Axis YI and Y-Axis Y2
- Z Axis minimum input level : TTL Level
- Component Test Facility
- Calibration Signal : Square wave of 0.5V at 1kHz
- CTR Display size : 8cm x 10cm
- Auxiliary Power Supply : 230V 50Hz AC
Different Frequency Ranges also available.
- Description
Description
This is a portable type of Oscilloscope for two traces. The band width is 0-20MHz. The instrument is of easy operation with comfortable controls. Its reasonable structure and technology makes it convenient to repair and calibrate.
- Dual Trace Dual Channel Oscilloscope with Component Test Facility
- Bandwidth : 20MHz
- Full bandwidth sweeping circuit is used in the sweeping system
- The flexible and convenient triggering mode has the functions for
selecting signals from one channel or triggered by Ext signals - ALT trigger to observe signals from two irrelative channels
- The instrument has the functions of TV-H / TV-V synchronization and
trigger-lock to observe all kinds of signals stably - From the terminal for trigger input, CH1 and CH2 signals can be output along
with the triggering channel to connect the Ext frequency counter - Y deflection operation : Y1, Y2, ALT, CHOP, ADD, mode X-Y
- Vertical Deflection : 5mV/Div to 20V/Div in factor 1-2-5 sequence in 12 steps
- Rising time : < 18nS
- Maximum Input Voltage : 400V (DC +Acp-p)
- Triggering Source : Y1, Y2, ALT, POWER, EXT
- Trigger Coupling : AC/DC (EXT), NORM/TV-H, TV-V
- Horizontal Sweep Mode : AUTO, TRIG, LOCK, SINGLE
- Sweep time factor : 0.1uS/div to 0.2s/div in 1-2-5 sequence in 20 steps
- Magnification : x10
- X-Ymode input : X-Axis YI and Y-Axis Y2
- Z Axis minimum input level : TTL Level
- Component Test Facility
- Calibration Signal : Square wave of 0.5V at 1kHz
- CTR Display size : 8cm x 10cm
- Auxiliary Power Supply : 230V 50Hz AC
Different Frequency Ranges also available.